Integrating 4 models & New standard for tachometers

Renewal of digital tachometer lineup.
A new digital tachometer "TM-4000 series" has been released by remodeling the TM-3100 series and integrating a multi-function tachometer, reversible counter, and passing time/passing speedometer.
Pursued high precision and high response while maintaining the functions and performance of the existing models. You can customize it by selecting the input format according to the external devices or detectors to be connected and combining various functions such as analog output, comparator output, DC power supply, etc.
The TM-4000 series meets diversifying needs for rotational speed measurement and realizes DX, smart factories.

Features



Product lineup selecting from 4 models

TM-4100 series

Card Image

1-channel input for basic measurement

Achieves improvement of basic performance and compatibility with the existing models. You can use your current detectors, cables, and mounting jigs as they are.
(Successor model: TM-3100 series)

TM-4200 series

Card Image

2- channel input for measurement of rotation speed differences/rotation speed ratio

Renewed to a compact body. Accurate quality inspection and machine control with 1 ms high speed sampling.
(Successor model: TM-5100)


TM-4300 series

Card Image

Reversible Counter for multiplication/addition/subtraction

Increased the accumulated pulse counts significantly and the display digits to 7 digits for line control such as accurate positioning and winding length measurement.
(Successor model: RV-3150)


TM-4400 series

Card Image

Passing Time/Passing Speedometer

Measureable cycle from 0.1 ms to 3600s Simultaneous measurement of passing time and passing speed between two points.
(Successor model: ST-1210)


Achieves the rotation speed measurement over a wide range with high accuracy, high response

For analog output, the linearity has been improved to 0.1% FS and the refresh time to1 ms.
Realizes highly accurate equipment monitoring and highly responsive control.
Input signals are compatible with sine waves from 1 Hz to 100 kHz and square wave pulses from 0.05 Hz to 100 kHz.
Square waves can be detected with a minimum pulse width of 4 μs.


Clearly visible on the organic EL display

The design of the display has been renewed. Visibility has been improved by adopting organic EL. The menu is displayed in a list on the setting screen, making it easier to use.

Card Image

Main display

Card Image

Setup screen


Ethernet selectable
Customized according to the connected device

The TM-4000 series can be customized according to the external device to be connected. Various functions such as voltage input, comparator output, and DC power supply can be combined. Ethernet* is available for external communication functions, which supports the construction of factory networks.

*Optional function

Card Image


Low-pass filter with improved noise immunity

The low-pass filter of the input unit can be selected from OFF/100 Hz/20 kHz. 100Hz is added to improve noise immunity.
(Equipped as standard on all models)

Card Image


The set time range of the auto zero function expanded

The setting time range of the Auto zero function has been expanded
to 0.0 (OFF) to 20.0 s. 0.5 second intervals can be set.
(Equipped as standard on the TM-4100 and TM-4200 series)

(Example) When the setting time is 1 second

For pulse input 1P/R

Card Image

Renewed the rapid deceleration follow-up function

While the measurement value is zero at the auto zero set time, the deceleration calculation is performed every 1 ms, or the measurement value is held.
(Equipped as standard on the TM-4100 and TM-4200 series)


Displays 0 r/min after auto zero setting time or maximum 20s


Product Lineup

Standard models

A new standard digital tachometer with exactly the functions you want. It is also recommended for those want to quickly consider a replacement for an existing model.

Product type Model name Output type Power supply type Existing model
1-ch input TM-4110 For display AC TM-3110
TM-4120 BCD output AC TM-3120
TM-4130 Analog output AC TM-3130
TM-4140 Comparator output AC TM-3140
TM-4111 For display DC
TM-4121 BCD output DC
TM-4131 Analog output DC
TM-4141 Comparator output DC
2-ch input TM-4270* Analog output / Comparator output / 2-ch Voltage input AC TM-5100
Reversible counter TM-4370* Analog output / Comparator output / 2-ch Voltage input AC RV-3150
Passing time/Passing speedometer TM-4470* Analog output / Comparator output / 2-ch Voltage input AC ST-1210

* BCD output is not supported.


Overview of Standard models


TM-4110/4111

  • Standard models for display only

TM-4120/4121

  • 6-digit BCD output
  • Open collector output that can be directly connected to a PLC
  • In addition to the normal mode that refreshes the output at
    regular intervals, the request mode that refreshes the output
    on demand is available.

TM-4130/4131

  • Selectable voltage output or current output
  • 1 ms rapid output refresh time
  • Highly accurate linearity of 0.1% FS for voltage output
    and 0.1% of span for current output

TM-4140/4141

  • Equipped with three contact outputs,
    and evaluation conditions can be set for each.
  • Can be used for alarm control, etc.
  • Comparison cycle every 1 ms.
  • Equipped with diverse output functions.


TM-4270

  • Wide input frequency range: 0.05 Hz to 100 kHz
  • 2 ch calculation function
    (rotation difference/rotation ratio/rate of change/rotation direction)


TM-4370

  • Reversible counter that measures linear position,
    displacement, dimensions, etc.
  • Wide input frequency range: DC to 100 kHz
  • Reversible Counter function (±2,000,000,000 counts)
  • Multiplication function (×1/×2/×4)
    and counting direction switching function are equipped.


TM-4470

  • Calculates the passing speed from the distance
    and the passing time between two points.
  • The distance between two points can be set arbitrarily.
  • Enables passing time measurement at a minimum resolution of 1 μs.
  • Pulse detection condition setup function
    (HIGH/LOW level, rising edge/falling edge)





Customized models

You can customize the tachometer according to the connected sensors and external devices. These are made to order products by combining 7 types of signal input/output boards and 2 types of power supply boards.

Selectable measurement functions

  • 1-channel input rotation speed
  • 2-channel input rotation speed differences/rotation speed ratio
  • Reversible Counter for multiplication/addition/subtraction
  • Passing Time/Passing Speedometer

Selectable signal input/output types

  • Input: Voltage/Line driver
  • Output: Analog/Comparator/BCD*
  • Communication: RC-232C/Ethernet

* TM-4100 series only

Calculation functions
(optional software)

  • Achieved speed/time measurement mode
    Calculates the time required from the start condition to the stop instruction measurement value. (TM-4100, 4300 only)

STEP 1: Select measurement functions

1-channel input 2-channel input Reversible counter Passing time/Passing speed
TM-4100 TM-4200 TM-4300 TM-4400

SETP 2: Select boards

Card Image




  • Only one board can be installed in each slot.
  • Be sure to install a board in slot POWER and slot D.
  • BCD output board can be installed in only TM-4100.



POWER slot A slot
Comparator output
B slot
External communication
C slot
Analog output
D slot
Signal input
AC power supply board
TM-0400
Comparator output board
TM-0440
BCD output board
(Voltage output)
TM-0421
Analog output board
(For TM-4100)
TM-0431
1-ch Voltage input board
(For TM-4100)
TM-0405
DC power supply board
TM-0401
BCD output board
(Open collector output)
TM-0422
Analog output board
(For TM-4200/4300/4400)
TM-0432
2-ch Voltage input board
(For TM-4200/4300/4400)
TM-0406
  RS-232C communication board
TM-0450
Line driver input board
(For TM-4200/4300)
TM-0407
Ethernet communication board
TM-0460


STEP 3: Select optional software

Calculation function for TM-4100 Calculation function for TM-4300
TM-0470 TM-0480




Rotation detectors


Applications


TM-4100 series Digital Tachometer

Measuring the rotation speed of the roller shaft on the load side from the gear on the drive side

Measures the rotational speed of a motor shaft. By setting the gear ratio to the tachometer, it enables to calculate and display the rotation speed of a roller shaft (r/min) and the velocity (m/min) even though it is away from the detection position.




TM-4200 series 2 channel Digital Tachometer

Measurement of drawing on paper and glass manufacturing lines

Attach the rotation detectors to the rotating parts of the line and input signals to the TM-4200 series. The speed change rate between the reference roller and the other roller is displayed in the TM-4200 series. Thus, by adjusting the speed of each part of the line, it is possible to obtain stable product quality.




TM-4300 series Reversible Counter


Controlling to keep the marking position constant

By controlling the length and distance of materials and finished products flowing through the production line, the surplus generated during manufacturing can be minimized.



TM-4400 series Passing time/Passing Passing speedometer

AC servo actuator product inspection

Measures the passing time and passing speed between two points with a minimum resolution of 1 μs.





Specifications

Click to display

Common specifications

Input unit

TM-4100/TM-4200
Number of channels [TM-4100] 1ch
[TM-4200] 2ch, 1ch (2-phase)
Input format Voltage input or no-voltage input (open collector residual voltage less than 1 V)
Input amplification format Selectable from AC or DC
AC amplifier Sine wave input 0.2 to 30 Vrms
Square wave input 0.6 to 42 Vp-p
Input frequency 1 Hz to 100 kHz
DC amplifier Input signal Square waveform having a pulse width of 4 µs or more
Input voltage range Hi: 4 to 30 V/Lo: -1 to 1 V
Input frequency 0.05 Hz to 100 kHz
Time measurement [TM-4100] 10 ms to 3600 s
Input impedance 10 kΩ or more
Low-pass filter [TM-4100] Selectable from OFF/100 Hz/20 kHz
[TM-4200] Selectable from OFF/100 Hz/20 kHz
                 (CH-A/CH-B common setups)
Input connectors [TM-4100] Terminal block (D slot SIG-COM1 terminal)
[TM-4200] Phoenix Contact terminal block
                 (D slot SIG-A-COM1 terminal/SIG-B-COM1 terminal)
TM-4300/TM-4400
Number of channels [TM-4300] 1ch (2-phase)
[TM-4400] 2ch
Input format Voltage input or no-voltage input (open collector residual voltage less than 1 V)
Input amplification format DC
DC amplifier Input signal Square waveform having a pulse width of 4 µs or more
(when the low-pass filter is OFF)
Input voltage range Hi: 4 to 30 V/ Lo: -1 to 1 V
Input frequency DC to 100 kHz
Input impedance 10 kΩ or more
Low-pass filter Selectable from OFF/100 Hz/20 kHz
(CH-A/CH-B common setups)
Input connectors Phoenix Contact terminal block
(D slot SIG-A-COM1 terminal/SIG-B-COM1 terminal)

Functional calculation method

TM-4100
Calculation method Periodic calculation method
Measurement accuracy Within displayed value x (±0.01%) ± 1 count
(count value excluding decimal point)
Measurement time Within 1 ms + 1 cycle time
Auto zero function Sets the total measurement value to zero if no input signal is detected for a specified time.
• Selectable between 0.0 s (OFF) and 20.0 s
(However, up to 3600 s can be measured when measuring time)
Rapid deceleration follow-up function • Function ON: Deceleration calculation is performed while the measurement value is zero at the auto zero set time.
• Function OFF: Measurement value is held while the measurement value is zero at the auto zero set time.
Moving average function 1 to 1280
Start-stop measurement function Calculates the average/maximum/minimum values from start to stop.
Measurement items Selectable from rotation speed/circumferential speed/moving speed/period/
number of times/frequency/flow rate/passing time/user-defined engineering unit
TM-4200
Calculation method Periodic calculation method
Measurement accuracy Single CH (CH-A or CH-B) Within displayed value × (±0.01%) ± 1 count
(count value excluding decimal point)
B/A or (B-A)/A 2 × (Single CH measurement accuracy)
B-A ± (CH-B measurement accuracy)
± (CH-A measurement accuracy)
Measurement time Within 1 ms + 1 cycle time
Auto zero function Sets the total measurement value to zero if no input signal is detected for a specified time.
• Selectable from 0.0 (OFF) to 20.0 s
Rapid deceleration follow-up function • Function ON: Deceleration calculation is performed while the measurement value is zero at the auto zero set time.
• Function OFF: Measurement value is held while the measurement value is zero at the auto zero set time.
Moving average function 1 to 1000
Start-stop measurement function Calculates the maximum/minimum values from start to stop and the average
value over the most recent set time.
Measurement items Selectable from rotation speed/circumferential speed/moving speed/
frequency/user-defined engineering unit
TM-4300
Counting range (internal counter) 0 to ±2 000 000 000
TM-4400
Measurable cycle 0.1 ms to 3600 s
Minimum resolution 1 µs
Measurement range 10 s/1000 s/3600 s

Setting Section

● Setting section
TM-4100/TM-4200
Measurement condition preset function Up to four measurement settings can be saved and loaded for use.
Pulse setting 1 to 999 999 P/R
Rotating body diameter setting 0.1 to 99 999.9 mm
Pulse interval setting 0.1 to 99 999.9 mm
Processing length setting [TM-4100] 0.1 to 99 999.9 mm
Pulse factor 0.00001 × 10E-3 to 9.99999 × 10E+3 EU/Pulse
TM-4300
Measurement condition preset function Up to four measurement settings can be saved and loaded for use.
Multiplication × 1/× 2/× 4
Offset function 0 to ± 9 999 999
Counting direction switching function +/–
Pulse factor 0.00001 × 10E-3 to 9.99999 × 10E+3 EU/Pulse
TM-4400
Measurement condition preset function Up to four measurement settings can be saved and loaded for use.
Measurement mode Single/Dual
Measurement conditions When measurement mode is Single:
• High level
• Low level
• Rising edge to rising edge
• Falling edge to falling edge
When the measurement mode is Dual:
• Rising edge to rising edge
• Falling edge to falling edge
• Rising edge to falling edge
• Falling edge to rising edge
Measurement item Selectable from passing time/passing speed
Measurement distance 0.1 to 99 999.9 mm
Prescale function 0.00001 × 10E-3 to 9.99999 × 10E+3 EU/Pulse

Display Section

Display section
TM-4100
Display unit OLED Display
Display update rate 0.2 s/0.4 s/0.5 s/0.6 s/0.8 s/1.0 to 10 s (1.0 s increments)
Unit display Rotation Speed r/s, r/min, r/h
Circumferential Speed mm/s, m/s, mm/min, m/min
Linear Speed mm/s, m/s, mm/min, m/min, km/min, mm/h, m/h, km/h
Cycle s, min
Frequency Hz, kHz
Count 1/s, 1/min, 1/h
Flow Rate mL/s, mL/min, mL/h, L/s, L/min, L/h
Passing time s, min
User-defined
engineering unit
EU/s, EU/min, EU/h
Number of display digits 6 digits
Number of decimal points Selectable from OFF/1/2/3
Number of zero-fixed
display digits
Selectable from OFF/1/2 digits
SIG indicator Blinks in synchronization with the input signal
Error display Backup memory error/board error/input frequency over/display digit over
Brightness selection Selectable from LO/MID/HI
TM-4200
Display unit OLED Display
Display refresh cycle 0.2 s/0.5 s/1 s
Unit display Rotation speed r/s, r/min, r/h
Circumferential speed mm/s, m/s, mm/min, m/min
Moving speed mm/s, m/s, mm/min, m/min, km/min, mm/h, m/h, km/h
Frequency Hz, kHz
User-defined engineering unit EU/s, EU/min, EU/h
Number of display digits 6-digit + sign
Number of decimal points Selectable from OFF/1/2/3/4/5 digits
Number of
zero-fixed display digits
Selectable from OFF/1/2 digits
SIG indicator Blinks in synchronization with the input signal.
Error display Backup memory error/board error/input frequency over/display digit over
Brightness Selection Selectable from LO/MID/HI
TM-4300
Display unit OLED Display
Display refresh cycle 0.2 s/0.5 s/1 s
Unit display OFF/mm/m/Count/s
Number of display digits 7 digits + sign
Number of decimal points Selectable from OFF/1/2/3/4/5/6 digits
SIG indicator Blinks in synchronization with the input signal.
Error display Backup memory error/board error/ pulse count over/display digit over
Brightness selection Selectable from LO/MID/HI
TM-4400
Display unit OLED Display
Unit display Passing time (TIME): ms, s
Passing speed (P.SPEED): m/s, km/h
Number of display digits 6 digits
Number of decimal points Selectable from OFF/1/2/3 digits
SIG indicator Blinks in synchronization with the input signal.
Error display Backup memory error/board error/display digit over/time measurement range over
Brightness selection Selectable from LO/MID/HI

Pulse Output

● Pulse output (TM-4100 only)
Output voltage Hi: 4.5 V or more/Lo: 0.5 V or less
Output logic Negative rogic
Load resistance 100 kΩ or more

Power supply for detector

Output voltage 12 VDC ± 10%
Maximum output current [TM-4100] 100 mA
[TM-4200/4400] Total of 2 channels 180 mA
[TM-4300] 180 mA

General specifications

Equipment type Built-in type
AC power supply model Power rating 100 to 240 VAC ± 10%, 50/60 Hz, 30 VA max.
Power consumption TM-4110: 19 VA max.
TM-4120: 21 VA max.
TM-4130: 25 VA max.
TM-4140: 21 VA max.
TM-4100 other configurations: 30 VA max.
TM-4270: 27 VA max.
TM-4370: 27 VA max.
TM-4470: 27 VA max.
TM-4200/4300/4400 Other configurations: 30 VA max.
DC power supply model Power rating 12 to 24 VDC ± 5%, 1.25 A max.
Power consumption TM-4111: 7 W max.
TM-4121: 7 W max.
TM-4131: 9 W max.
TM-4141: 7 W max.
TM-4100 other configurations: 15 W max.
TM-4200/4300/4400: 15 W max
Safety Overvoltage Category II
Insulation Double insulation structure
Insulation resistance Between power supply +/- terminals and FG terminal: 10 MΩ or more
(at 500 VDC)
Operating environment Indoor use only
Operating temperature and humidity 0 to 50 ℃/30 to 80 %RH (no condensation)
Storage temperature and humidity -10 to 60 ℃/30 to 85 %RH (no condensation)
Degree of contamination 2
Altitude 2000 m max
Outer dimensions 96 (W) x 48 (H) x 140 (D) mm max.
Weight [TM-4110] Approx. 340 g
[TM-4270/4370/4470] Approx. 400 g

Applicable standards

CE marking Low Voltage Directive 2014/35/EU Standard EN 61010-1
EMC Directive 2014/30/EU Standard EN 61326-1
RoHS Directive 2011/65/EU Standard EN IEC 63000
FCC/Canada FCC part 15B
ICES-003(A)/NMB-003(A)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. canada: CAN ICES-003(A) / NMB-003(A)

Accessories

TM-4100
Mounting jig  1 set (2 pcs)
Instruction manual 1 pcs
TM-4200/4300/4400
Input connector for D slot made by Phoenix Contact 1 pcs (packed in the D slot)
Mounting jig 1 set (2 pcs)
Instruction manual  1 pcs
Power supply, Signal input/output boards

TM-0400/TM-0401 Power Supply Board

TM-0400
Power rating AC100 V to 240 V ± 10 %, 50/60 Hz, 30 VA max
Power consumption 30 VA max
TM-0401
Power rating DC12 V to 24 V ± 5 %, 1.25 A max
Power consumption TM-4200/4300/4400: 15 W max

TM-0405/0406 Input Voltage Board

Voltage input specifications Same as Input unit
Input connector [TM-0405] Terminal block (D slot SIG-COM1 terminal)
[TM-0406] Phoenix Contact terminal block
(D slot SIG-A-COM1 terminal/SIG-B-COM1 terminal)

TM-0407 Line Driver Signal Input Board

Line driver signal input1 specifications Equivalent to RS-422A
Accessory FMC 1,5/10-ST-3,5 1952348x1
(PCB terminal block made by Phoenix contact)

TM-0421/0422 BCD Output Board (TM-4100 series only)

● Output specifications
Output form 6-digit parallel output
Output format [TM-0421] 5 V internal pull-up output
[TM-0422] NPN open collector output
Sink current 32 mA max
Output withstand voltage 24 V max
Output logic Positive logic
Data refresh time 100 ms or less
● Operation modes
Normal mode Continuously refresh output every 100 ms
(continuous print command output every 100 ms).
Request mode Refresh output when request signal is received
Card Image
● Request signal input specications
Input form Negative logic (pulse width 10 μs or more)
Operating edge Falling edge
Input voltage Hi: 4.2 to 5.25 V/Lo: 0 to 0.9 V
● Pin number and Signal name

Card Image

BCD terminal pin assignment

Pin Signal Pin Signal Pin Signal
1 BCD output 1×10 0 13 BCD output  1×10 3 25 Start input
2 2×10 0 14 2×10 3 26 Stop input
3 4×10 0 15 4×10 3 27 Reset input
4 8×10 0 16 8×10 3 28 NC
5 BCD output  1×10 1 17 BCD output 1×10 4 29 NC
6 2×10 1 18 2×10 4 30 NC
7 4×10 1 19 4×10 4 31 NC
8 8×10 1 20 8×10 4 32 NC
9 BCD output 1×10 2 21 BCD output 1×10 5 33 Data request
10 2×10 2 22 2×10 5 34 NC
11 4×10 2 23 4×10 5 35 Print command
12 8×10 2 24 8×10 5 36 GND

TM-0431/0432 Analog Output Board

TM-0431
Number of output channels 1 ch
Output type Selectable from voltage or current
Output method 16-bit D/A conversion
Output refresh time Selectable from 1 ms/10 ms/20 ms/50 ms/100 ms/200 ms/500 ms/1 s
Voltage output Output range Selectable from 0 to 10 V/0 to 5V/1 to 5 V
Load resistance 100 kΩ or more
Linearity ± 0.1 % FS
Zero temperature drift ± 0.05 % FS/℃
Span temperature drift ± 0.05 % FS/℃
Current output Output range Selectable from 4 to 20 mA or 0 to 16 mA
Load resistance 500 Ω or less
Linearity ± 0.1 % of span
Zero temperature drift ± 0.05 % of span/℃
Span temperature drift ± 0.05 % of span/℃
Output format Terminal block
TM-0432
Number of output channels 1 ch
Output type Voltage
Output method 16-bit D/A conversion
Output refresh time 1 ms
Voltage output Output range ±10 V
Load resistance 100 kΩ 以上
Linearity ± 0.1 % FS
Zero temperature drift ± 0.05 % FS/℃
Span temperature drift ± 0.05 % FS/℃
Output format Terminal block

TM-0440 Comparator Output Board

Contact output 1 make contact output × 3 (COMP1/COMP2/COMP3)
・Evaluation conditions can be set individually.
Evaluation conditions UPPER [TM-4100/4200/4400] 6-digit setup
[TM-4300] 7-digit setup
  • Relay turns ON when UPPER ≦ main measurement value
LOWER [TM-4100/4200/4400] 6-digit setup
[TM-4300] 7-digit setup
  • Relay turns ON when LOWER > main measurement value
OK Relay turns ON when all comparators set to UPPER or LOWER are OFF.
ERROR Relay turns ON when non-communication error occurs.
Contact operation modes Automatic recover mode After the relay turns ON, the relay returns to OFF when the evaluation conditions are no longer satisfied
(0 to 20% hysteresis can be set for the UPPER and LOWER evaluation conditions).
Hold mode [TM-4100/4200/4300]
Once the relay turns ON, it remains ON even if the evaluation conditions are no longer met.
Shot output mode When the relay ON condition is met, it remains ON for the specified time and then returns to OFF.
(Settable time: 10 to 2000 ms, in 10 ms increments)
Output delay function [TM-4100/4200/4300]
Relay turns ON when the setup value is exceeded continuously for the set time. (Settable time: 0 to 1000 ms, in 10 ms increments)
Reset function [TM-4100/4200/4300]
Resets the relay to OFF in the hold mode
Maximum contact capacity 30 VDC/1 A
250 VAC/1 A
Output refresh time Approx. 10 ms
Output format Terminal block

TM-0450 RS-232C Board

■ TM-0450 RS-232C Board
Card Image
● Communication specifications
Baud rate 9 600/19 200/115 200 bps
Data bits 8 bit
Parity None
Stop bits 1-bit
Flow control Hardware
Terminator CR+LF

TM-0460 Ethernet Board

■ TM-0460 Ethernet Board
Card Image
● Ethernet communication specifications
Electrical specifications IEEE802.3 compliant
Transmission method 10BASE-T/100BASE-T automatically selected
Communication protocol Socket communication by TCP/IP (IPv4)

Gate Signal Input

■ Gate Signal Input
(Valid when any of the BCD output, RS-232C communication, or Ethernet communication board is installed)
Gate function [TM-4100/4200] START/STOP/RESET
[TM-4300] START•STOP/OFFSET/RESET
[TM-4400] START/RESET
Voltage input Hi: 4.2 to 5.25 V/Lo: 0 to 0.9 V
Non-voltage input Open voltage: 5 V ± 0.25 V
Short-circuit current: 1 mA max.
Contact resistance: 50 Ω or less
Gate signal timing

Card Image

[TM-4300] When the START/STOP terminal is at low level, measurement is stopped.
[TM-4400] When the START terminal is at low level, measurement is in progress.
Optional software

TM-0470/0480 Calculation function*

Achieved speed/time measurement mode
TM-0470
Calculation details Calculate the time required from the start condition to the stop instruction measurement value.
Calculation item Selectable from rotation speed/circumferential speed/moving speed
Unit of measurement s (fixed display)
Start instruction value 0 to 999 999 *Decimal point position follows the setting.
Stop instruction value 0 to 999 999 *Decimal point position follows the setting.
TM-0480
Calculation details Calculate the time required from the start condition to the stop instruction measurement value.
Calculation item Pulse accumulated value
Unit of measurement s (fixed display)
Start instruction value Start the time measurement when reaching to the measurement start state.
Stop instruction value -9 999 999 to 9 999 999
*Decimal point position follows the setting.
*Function added to the main unit as an option.

Table of optional boards/software combination

Slot POWER A B C D Software
Specifications Power Comparator output
BCD output
RS-232C
communication

Ethernet
communication

Analog
output
Voltage input Line driver inputt Calculation function
AC DC Voltage output Open collector output 1ch 2ch 2ch
Model name TM-0400 TM-0401 TM-0440 TM-0421 TM-0422 TM-0450 TM-0460 TM-0431 TM-0432 TM-0405 TM-0406 TM-0407 TM-0470 TM-0480
TM-4100        
TM-4200        
TM-4300        
TM-4400          



  • Only one board can be installed in each slot.
  • Be sure to install a board in slot POWER and slot D.

 

Card Image


Product list

Standard models

Model Product name
TM-4110 Digital Tachometer (Display only/AC power supply)
TM-4111 Digital Tachometer (Display only/DC power supply)
TM-4120 Digital Tachometer (BCD output/AC power supply)
TM-4121 Digital Tachometer (BCD output/DC power supply)
TM-4130 Digital Tachometer (Analog output/AC power supply)
TM-4131 Digital Tachometer (Analog output/DC power supply)
TM-4140 Digital Tachometer (Comparator output/AC power supply)
TM-4141 Digital Tachometer (Comparator output/DC power supply)
TM-4270 2-channel Digital Tachometer (Analog output/Comparator output/AC power supply/2-ch input)
TM-4370 Reversible Counter (Analog output/Comparator output/AC power supply/2-ch input)
TM-4470 Passing Time/Passing Speedometer (Analog output/Comparator output/AC power supply/2-ch input)
*Installation of optional boards after delivery needs to be done in our factory, please ask for further information to our sales staff or the distributor.

Customized models

Model Product name
TM-4100 TM-4100 series base
TM-4200 TM-4200 series base
TM-4300 TM-4300 series base
TM-4400 TM-4400 series base
TM-0400 AC power board
TM-0401 DC power board
TM-0405 1-ch input board for TM-4100
TM-0406 2-ch input board for TM-4200/4300/4400
TM-0407 Line driver signal input board
TM-0421 BCD output board (voltage output)
TM-0422 BCD output board (open collector output)
TM-0431 Analog output board for TM-4100
TM-0432 Analog output board for TM-4200/43004400
TM-0440 Comparator output board
TM-0450 RS-232C board
TM-0460 Ethernet board
TM-0470 Calculation function for TM-4100
TM-0480 Calculation function for TM-4300

 

 

updated:2024/04/23