FP-5000 series

Achieves accurate and wide range of mass flow measurement from small to large flow rate

In engine evaluations such as emission mode tests and transient tests for performance evaluation, the evaluation methods have been shifting from steady-state tests to transient tests. In the evaluation of fuel consumption, the requirement for evaluating the fuel consumption characteristics in transient duration has been increasing as well as the total fuel consumption for each mode. The FP-5000 series has achieved high pulse resolution and wide measurement range. It enables to detect changes in the flow rate effectively and responsively, and measure large flow rate. It can be used when the flow rate increases, such as when measuring alcohol fuel.

Features

 

1.Measuring even small amount of changes in the flow rate

Achieves 0.0005 mL/pulse resolution (when using FP-5130 series, up to 20 times of the existing models)


Instantaneous massflow measurement at starting engine

Integrated mass flow rate test during fuel injection by an injector

 Installation method of FP-5000 series Flow Detector

Installation method of FP-5000 series Flow Detector



2. Wide detector lineup supports from small to large flow rate

There are a wide range of flow detectors, which can be used for various applications from idling to WOT with a single detector.








3. Compact and space-saved design

A filter, the Volumetric Flow Detectors FP-5000 series, a flow detector, and a temperature/pressure sensor unit can be connected together, and achieved space saving.



4. Applicable to alcohol mixed fuel as standard

The flow detector is applicable to alcohol as standard.
The detector can be used without modification in the fuel flow measurement of engines that often use alcohol fuel.







System configuration

Figure of FP-5000 system configuration



Specifications

Standard type Small flow rate type Medium flow rate type Large flow rate type
Series FP-5130 series FP-5140 series FP-5150 series
  FP-5130 series FP-5140 series FP-5150 series
 
Usable liquid Gasoline, light oil, kerosene, alcohol, biofuel and general petroleum-based hydraulic oi (*1)
Measurement range Flow rate FP-5131/5132 : 0.05 to 60 L/h
FP-5133/5134 : 0.05 to 108 L/h
(*2)
FP-5141/5142 : 0.3 to 300 L/h
FP-5143/5144 : 0.3 to 600 L/h
FP-5151/5152 : 1 to 1440 L/h
Accuracy Flow rate Within ±0.0009 L/h
(0.05 to 0.18 L/h )
Within ±0. 5 % of reading
(0.18 to 108 L/h) 
Within ±0.2% of reading Within ±0. 5 % of reading
Pressure loss 8 kPa or less
(at 40  L/h <gasoline>)
2 kPa or less
(at 60 L/h <gasoline>)
7.5 kPa or less
(at 500  L/h <light oil>)
Operating temperature liquid 0 to +65 °C 0 to +65 °C 0 to +65 °C
ambient 0 to +65 °C 0 to +65 °C 0 to +65 °C
Inlet/ outlet port Size IN: Rc3/8 (*3)
OUT: Rc3/8 (*3)
IN: Rc3/8 (*3)
OUT: Rc3/8(*3)
IN: Rc1/2
OUT: Rc1/2
Maximum operating pressure 1 MPa 1 MPa 3.4 Mpa
Temperature/ pressure sensor unit EH-0830 EH-0830 EH-0850
Measurement range Temperature 0 to +100 °C 0 to +100 °C 0 to +100 °C
Pressure 0 to 1 MPa 0 to 1 MPa 0 to 1 MPa
Accuracy Temperature PT100 Ω A class PT100 Ω A class PT100 Ω A class
Pressure ±0.25 % F.S ±0.25 % F.S ±0.25 % F.S
Weight   Approx. 3.5 kg Approx. 5.0 kg Approx. 13.5 kg
Accessary   Instruction manual, line filter(EH-1130 or EH-1150), mounting bracket (Appropriate stand bracket for FP-5130/5140 series is supplied according to the selection of options.)  
Cable   Optional: FP-0015(5m), FP-0016(10m), FP-0017(20m)
Applicable flow meter Digital flow meters:
FM-2500A/ DF-0400A (*not applicable to FP-5132, 5134, 5142, 5144 and 5152)
DF-2200(*not applicable to FP-5132, 5134, 5142, 5144, 5151 and 5152)
FM-3100/ FM-0311A
Filter/ Element
Alcohol applicable Filter EH-1130 EH-1130 EH-1150
Element EH-0031A EH-0031 EH-0051A

Please take note that the instantaneous flow rate may be varied;
1.if the inlet pressure is lower than the pressure loss.
2.if the outlet of the detector is open to the atmosphere.
(*1) Please contact to your nearest distributor.
(*2) Made-to order for the measurement range from 0.02 L/h. Please contact to your nearest distributor.
(*3) Option joint (SAE joint) is available. Please contact to your nearest distributor.




Option

Model Product name Contents
FM-0312 FD additional connector For density input connection
FP-0015 Signal cable for flow rate 5 m Connection cable for FM/DF series
FP-0016 Signal cable for flow rate 10 m
FP-0017 Signal cable for flow rate 20 m
FP-0025 Temperature signal cable, 5 m Connection cable for FM/DF series
FP-0026 Temperature signal cable, 10 m
FP-0027 Temperature signal cable, 20 m
FP-0035 Pressure signal cable, 5 m Connection cable for FM/DF series
FP-0036 Pressure signal cable, 10 m
FP-0037 Pressure signal cable, 20 m
FD-0011 Density signal cable, 5 m Connection cable for FM series
FD-0012 Density signal cable, 10 m
FD-0013 Density signal cable, 15 m
EH-0830 Temperature/pressure sensor units for FP-513X, FP-514X For FP-513x, FP-514x
EH-0830 is a combination of EH-0081 and EH-0082
EH-0850 Temperature/pressure sensor units for FP-515X For FP-515x
EH-0731 Mounting bracket for FP513x (single unit) 1UNIT: Flow detector including line filter
EH-0732 Mounting bracket for FP513x (2 units) 2UNIT: Flow detector + Density meter or Temperature/pressure sensor unit
EH-0733 Mounting bracket for FP513x (3 units)   3UNIT: Flow detector + Density meter + Temperature/pressure sensor unit
EH-0741 Mounting bracket for FP514x (single unit) 1UNIT : Flow detector including line filter
EH-0742 Mounting bracket for FP514x (2 units) 2UNIT: Flow detector + Density meter or Temperature/pressure sensor unit
EH-0743 Mounting bracket for FP514x (3 units)   3UNIT: Flow detector + Density meter + Temperature/pressure sensor unit
EH-0730A Stand bracket for FP513x/514x When using the stand, use at vibration of 9. 8 m/s2 or less.


Revised:2022/10/17