Features

1. Mass flow rate measurement (intermittent measurement)
 
構造原理図

When the fluid surface goes below L3, a pressure signal from the differential pressure detector opens an electromagnetic valve (V1) to allow more fluid to enter. V1 closes once the fluid surface reaches L2, and after about two seconds the device begins measuring instantaneous flow. The output of the differential pressure detector varies according to the mass of discharged fluid as the fluid surface goes down from L2 as fluid is discharged from the flow detector. When used in combination with the FM-3100 Digital Flow Meter (FM-0331 FX Module installed), the flow can be displayed digitally as a mass reading based on the amount of this variance.

 

 

2. Using pressurized flow
 
Using pressurized flow

The air release port is so that air may flow in and out of the detector as fluid flows in and out. Normally, a pipe is connected to the air layer of the fluid supply tank. It is also possible to pressurize to flow fluid to the measured object by connecting the constant compressed air to this port.



System configuration


Specifications

FX-1110 FX-1120 FX-1130
Usable liquid Standard Gasoline, light-oil, kerosene, general petroleum-based hydraulic oil
Alcohol applicable (option) Gasoline, light oil, kerosene, general petroleum-based hydraulic oil,
methanol, ethanol or mixture alcohol and gasoline
Measurement range 0 to 10 g/s
(0 to 36 kg/h)
0 to 25 g/s
(0 to 90 kg/h)
0 to 50 g/s
(0 to 180 kg/h)
Accuracy *1 Within ±0.2% of reading value, ±0.01% of full scale
Resolution 0.001 g/s 0.01 g/s
Minimum cumulative unit 0.01 g 0.1 g
Maximum cumulative flow
(One fill-up)
200 g 500 g 1000 g
Operational temperature range*2 0 to +40 °C (ambient temperature and fluid temperature, non-freezing)
Joint Rc 3/8 inner diameter ø6,
outer diameter ø9, hose nipple
Rc 1/2 inner diameter ø12, outer diameter ø16
hose nipple
Pressure resistance 196 kPa
Outer dimension 310(W) × 597(H) × 198(D) mm
Weight Approx. 13 kg
Power supply Supplied from FM-3100 Digital Flow Meter
Accessories Instruction manual
Flow signal cable (option) FX-0021 (5m), FX-0022 10m), FX-0023 (20m)
Applicable flow meter FM-3100 Digital Flow Meter + FM-0331 FX module
FM-2500A Digital Flow Meter* + FX-0400 FX module * Discontinued products

*1: When the temperature changes rapidly during measurement, the above accuracy can not be guaranteed.
*2: The vapor phenomenon may prevent normal measurement in this temperature range.



Option

Model Product name Remarks
FX-0021 Flow signal cable (5 m)
FX-1100 series FX-0400A(FM-2500A*)* discontinued product
FX-1100 series FM-0331(FM-3100)
FX-0022 Flow signal cable 10 m
FX-0023 Flow signal cable 20 m

Last update :2022/09/27