Mass Burette Flow Detector
FX-1100 Series
Made to order

The FX-1100 Series Mass Burette Flow Detector takes the position of the fluid surface inside the burette as the head pressure using the differential pressure detector attached at the bottom and directly measures the flow of fluid as a mass based on changes in this pressure. It does not require calculation correction of temperature and specific gravity, and has many advantages such as high accuracy and extremely less affected by air bubbles, which enable to measure fuel consumption in the tests such as chassis dynamometer and engine bench. The 3 models are available according to the measurement range and application.
Features

When the fluid surface goes below L3, a pressure signal from the differential pressure detector opens an electromagnetic valve (V1) to allow more fluid to enter. V1 closes once the fluid surface reaches L2, and after about two seconds the device begins measuring instantaneous flow. The output of the differential pressure detector varies according to the mass of discharged fluid as the fluid surface goes down from L2 as fluid is discharged from the flow detector. When used in combination with the FM-3100 Digital Flow Meter (FM-0331 FX Module installed), the flow can be displayed digitally as a mass reading based on the amount of this variance.

The air release port is so that air may flow in and out of the detector as fluid flows in and out. Normally, a pipe is connected to the air layer of the fluid supply tank. It is also possible to pressurize to flow fluid to the measured object by connecting the constant compressed air to this port.
System configuration

Specifications
FX-1110 | FX-1120 | FX-1130 | ||
---|---|---|---|---|
Usable liquid | Standard | Gasoline, light-oil, kerosene, general petroleum-based hydraulic oil | ||
Alcohol applicable (option) | Gasoline, light oil, kerosene, general petroleum-based hydraulic oil, methanol, ethanol or mixture alcohol and gasoline |
|||
Measurement range | 0 to 10 g/s (0 to 36 kg/h) |
0 to 25 g/s (0 to 90 kg/h) |
0 to 50 g/s (0 to 180 kg/h) |
|
Accuracy *1 | Within ±0.2% of reading value, ±0.01% of full scale | |||
Resolution | 0.001 g/s | 0.01 g/s | ||
Minimum cumulative unit | 0.01 g | 0.1 g | ||
Maximum cumulative flow (One fill-up) |
200 g | 500 g | 1000 g | |
Operational temperature range*2 | 0 to +40 °C (ambient temperature and fluid temperature, non-freezing) | |||
Joint | Rc 3/8 inner diameter ø6, outer diameter ø9, hose nipple |
Rc 1/2 inner diameter ø12, outer diameter ø16 hose nipple |
||
Pressure resistance | 196 kPa | |||
Outer dimension | 310(W) × 597(H) × 198(D) mm | |||
Weight | Approx. 13 kg | |||
Power supply | Supplied from FM-3100 Digital Flow Meter | |||
Accessories | Instruction manual | |||
Flow signal cable (option) | FX-0021 (5m), FX-0022 10m), FX-0023 (20m) | |||
Applicable flow meter | FM-3100 Digital Flow Meter + FM-0331 FX module FM-2500A Digital Flow Meter* + FX-0400 FX module * Discontinued products |
*1: When the temperature changes rapidly during measurement, the above accuracy can not be guaranteed.
*2: The vapor phenomenon may prevent normal measurement in this temperature range.
Option
Model | Product name | Remarks |
---|---|---|
FX-0021 | Flow signal cable (5 m) | FX-1100 series FX-0400A(FM-2500A*)* discontinued product FX-1100 series FM-0331(FM-3100) |
FX-0022 | Flow signal cable 10 m | |
FX-0023 | Flow signal cable 20 m |
Related information
Last update :2022/09/27