CH-1200A is a high-performance charge amplifier to convert charge signal to voltage signal. Built-in integration function allows optimization of the signal which is input to the vibration data analyzer connected.

Changing into a multi-channel amplifier is easy by connecting multiple units.

 

Features

  • Built-in integration function – Output data can be selected from acceleration, velocity and displacement.
  • Filter function – High-pass filter and Low-pass filter remove unwanted vibration and enable more precise measurement.
  • Compact, light weight and easily changed to a multi-channel amplifier by connecting units.

Overview Specification

Maximum input charge ±100000 pC
Input connector Miniature connector
Charge condenser 100 pF, 1000 pF, 10000 pF

Leak resistance

10 GΩ, 1 GΩ, 100 MΩ
Frequency response characteristics

 

Accelerometer 1.0 Hz to 15 kHz ± 0.5 dB
0.2 Hz to 50 kHz ± 3 dB
Velocity 3.0 Hz to 3 kHz ± 0.5 dB
Displacement 3.0 Hz to 500 Hz ± 1 dB

(However, the frequency at 160 Hz to be 0 dB)

Accuracy

 

Acceleration ± 2 %
Velocity ± 3 %
Displacement ± 5 %

(at 160 Hz, 25 ℃ ±3 ℃)

Rated output voltage ±10 V
Maximum output load 3 mA, 1500 pF
Output connector C02(BNC)
Input conversion noise level 0.05 pC (rms) or less
Output offset ±5 mV or less
Sensitivity 0.01 to 999 pC/EU
Filter HPF: through, 3 Hz, 10 Hz(-18 dB/oct)
LPF: through, 1 kHz, 10 kHz(-18 dB/oct)
(10 Hz, 1 kHz are conform to "Mechanical Vibration of Rotating and Reciprocating Machinery-Requirements for Instruments for Measuring Vibration Severity"<JIS B 0907-1989>)
CAL signal(calibration) 160 Hz ± 5%, 80 Hz ± 5% 1 V0-p ± 2.0 % sine wave(25℃ ± 3℃)
Maximum input alarm display function OFF:[-10 dB/Over] indicator blinks in red when output exceeds ±10 V. The blinks will stop when the output goes within ±10 V.
ON: The blinking in red continues unless [▲/RST] switch is pushed when the output exceeds ±10 V.
Output sensitivity

 

Acceleration 0.01, 0.0316, 0.10, 0.316, 1.00, 3.16, 10.0, 31.6, 100, 316, 1000 mV/EU
Velocity 0.01, 0.0316, 0.10, 0.316, 1.00, 3.16, 10.0, 31.6, 100, 316, 1000 mV/EU
Displacement 0.10, 0.316, 1.00, 3.16, 10.0, 31.6, 100, 316, 1000 mV/EU

 

Auto power save Only the decimal point will be displayed on main display when there is no input from each switch for approx. 2 minutes of more.
Other function ·Output level indicator:Turns on in green at -10 dB/F.S., blinks in red at F.S. over.
·Condition memory:The measurement conditions are stored even though the power is OFF.
·Condition lock:Malfunction prevention key
Power requirement 10 V to 15 VDC
* AC 100 V : available by AC adapter (sold separately)
Consumption current 120 mA or less(When the value of 1.00 is shown at displayed device.)
Connection Up to 6 units for one AC adaptor
Outer Dimensions 28 (W) × 121(H) × 194 (D) mm(not included protruded section)
Mass Approx. 510 g
Working environment -10℃ to + 50℃, 90 % RH or less (with no condensation)
Storage environment -10℃ to + 50℃, 90 % RH or less(with no condensation)
Accessories Joint cable, stabilizer, connecting metal
Option ·PS-P20022C(PE1821078)AC adapter
·Power cable for oversea(Power cable for Japan:provided as standard)
       For North America (PE3530083)
       For Europe (PE3530085)
       For China (CCC):Please contact us.

Revised:2020/12/23



webinfo

 