DS-0299 has been discontinued. Successor model:DS-0399 (Click here)




 

Note

DS-0299 (USB interface for DS-2000 series: USB 2.0 supported) has been discontinued.

Successor model to replace the DS-2000 series with (Click here)

 

The DS-0299/DS-0399 are interfaces to connect the DS-2000/DS-3000 series Multi-channel data station with a personal computer having a USB port. The modification of the main units is not required.



Features

  • Can be used for a PC only with the USB2.0 port.
  • Compact and light weight design (W 112 mm, H 18 mm, D 43 mm, Weight 80 g)
  • The DS-0299 can attach to the rear side of the DS-2000 series main unit by hook-and loop fastener.
    (DS-2000 series only)
  • DS-0299
  • Useful for a small number of channels (up to 4-ch or 8-ch)

System Configuration

Applicable products

DS-0299
Discontinued
●Hardware DS-2100 / 2102 / 2102A / 2104 / 2104A(*1)
●Software Software for the DS-2000 series excluding the following
DS-0242 (Servo analysis)
OS-2000 series (OS-2700 OSRECO) *only less than Ver.2.5
XN-8000
DS-0399
●Hardware DS-3100 / 3102 / 3104(*1)
●Software

Software for the DS-3000 series excluding the following
DS-0342 (Servo analysis)

OS-2000 series (OS-2700 OSRECO) *only less than Ver.2.5

(*1) Both 40 kHz and 100 kHz units are available. However, the performance of throughput is limited.

Specifications

  DS-0299 Discontinued DS-0399
Throughput performance(*2) 100 kHz range / 2-ch
40 kHz range / 4-ch
20 kHz range / 8-ch
10 kHz range/ 16 ch
100 kHz range / 2-ch
40 kHz range / 8-ch
20 kHz range / 16-ch
Minimum spec. (CPU) Intel® Core 2 Duo (recommended : Intel® Core i5 or higher)
Interface USB 2.0 (USB Hub: cannot be used)(*3)
OS Windows® XP (32-bit), Windows Vista® (32-bit), Windows® 7, Windows® 10
Simultaneous analysis recording - Supported(*4)
Unit connecting interface
(FRAME LINK)
- Supported(*5)

(*2) Throughput condition: A/D over information and rotation speed information are included. Stored with 24-bit.
   However, regarding for the 100 kHz range, only A/D over information is included. Stored with 16-bit.
   Throughput performance may vary depending on a PC performance and operation conditions.

(*3) Some PCs may cause communication error when connected to the USB 3.0 port.
   In that case, please connect to the USB 2.0 port and use it.

(*4) The update speed may be decreased when 8 or more of analysis screens are displayed. There is no effect on the recorded data.

(*5) 100 kHz unit: Unit connection (FRAME LINK) is not supported.


 Revised:2020/07/02