On-Board Flow Meter
DF-2200
The DF-2200 On-Board Flow Meter is a compact on-board fuel flow meter developed for our FP series Volumetric Flow Detector. It accepts pulse signal SIG A and SIG B that have phase differences, and includes the backward flow correction function for back-flow.
Displaying and measuring the mass flow rate is possible by entering the value of standard density of the fuel in use, and its temperature and density coefficient (1/°C). Besides the flow rate, the items of time/ temperature (resistance temperature detectors)/ pressure (voltage input) can also be measured.
The DF-2200 outputs the voltage corresponding to the value of instantaneous flow rate/ temperature/ pressure, and outputs the pulse corresponding to the instantaneous flow rate. CAN and RS-232C (option) are also equipped with the external devices as a communication function.
This is the flow meter that is capable of not only on-board measurement but also measurement on engine bench.
Features
The flow rate/ temperature/ pressure can be measured with just one unit
System Configuration
Specification
DF-2200 On-Board Flow Meter | ||
---|---|---|
Applicable detector |
FP-4135, FP-213/213S, FP-3130/3130S, FP-3132/3132S, FP-2140H, FP-2240HA, FP-3140/3142, FP-2140S, MF-3200 |
|
Display method |
Fluorescent display tube, 11.45 mm× 69.85 mm (2-stage display) |
|
Display digit | Total flow |
ΟΟΟΟΟΟΟ.Ο • The decimal point is variable according to the weight per selected pulse The third decimal point: 0.001 mL/ Pulse The second decimal point: 0.01 The first decimal point: 0.1 • When the display value reaches its maximum, change and display the decimal point as follows; 0.000 to 99999.999, 100000.00 to 999999.99, 1000000.0 to 9999999. 9 • When the multiplication is ON, add one decimal digit to the above values. |
Instantaneous flow rate |
ΟΟΟ.ΟΟΟΟ • The decimal point is variable according to the weight per selected pulse. The third decimal point: 0.001 mL/ Pulse The second decimal point: 0.01 The first decimal point: 0.1 • When the multiplication is ON, add one decimal digit to the above values. |
|
Pressure | ΟΟΟΟ.Ο(without after the decimal point) • Display unit: kPa |
|
Temperature |
ΟΟΟ.Ο (to the first decimal point) • Display unit: °C |
|
Total time |
ΟΟΟΟ.ΟΟ (to the second decimal point) • Display unit: s • When the display digits become full, display the value by round up after the decimal point. |
|
Output section | Instantaneous flow rate |
Voltage output: 0 to 10 V (stamdard): 1 ≤ N ≤ 1000 (initial value N=30) (option): 1 ≤ N ≤ 10000 (initial value N=300) |
Temperature |
Voltage output: 0 to 10 V |
|
Pressure | Voltage output: 0 to 10 V (standard) : 1 ≤ N ≤ 100 (initial value N=20) (option) : 1 ≤ N ≤ 10000 (initial value N=200) |
|
Pulse output | Output item: Instantaneous flow rate |
|
Function section | Average instantaneous flow rate | Display the data obtained through moving average the instantaneous flow rate, updated and displayed per 500 ms or 1 s, by 0.5 to 10 s. |
Instantaneous flow rate analog output Indexation average |
OFF/ON (N=1 to 1000) |
|
Backward flow correction | Detect a backward flow and correct the flow amount | |
Density temperature correction function (convert into weight) | Correction function to know the weight flow from volumetric flow | |
Output calibration (CAL) | V_OUT ZERO: 0 V V_OUT FULL: 10 V |
|
Factor | 1000 to 100000 | |
CAN output | Protocol: Conforms to CAN Ver 2.0 B |
|
RS-232C (option) | Serial communication (Start-stop system): 9600 bps/ 38400 bps Connector: D-SUB 9PIN (male) |
|
General specification | Power source | Battery connecting: 10 to 28 VDC When using AC adapter (option): 100 to 240 VAC 50/60 Hz |
Current consumption | 28 VA or less (when 12 VDC) | |
Operating environment | Indoor, in a vehicle | |
Altitude | Elevation 2000 m or less | |
Operating temperature range | 0 to +50°C *Operating temperature range of AC adapter is 0 to +40°C | |
Storage temperature range | -10 to +60 °C | |
Operating humidity range | 5 to 80 % | |
Storage humidity range | 5 to 85 % | |
Outer dimension | 170(w) × 49(H) × 120(D) | |
Weight | Approx, 800g | |
Safety | IEC61010-1: Over-voltage category II Protection Class II Pollution level II • When using an optional AC adapter. |
|
Conforming standard | CE marking | LVD Directive 2014/35/EU Standard EN61010-1 (with AC adapter) EMC Directive 2014/30/EU Standard EN61326-1 RoHS Directive 2011/65/EU Standard EN50581 |
Accessory | Instruction manual×1 |