On-Board Volumetric Flow Detector
FP-4135
The FP-4135 On-Board Volumetric Flow Detector is the high-precision positive displacement flow detector to measure the fuel flow rate of liquids such as gasoline, light oil and kerosene combined with the Ono Sokki DF-2200 On-Board Flow Meter or the FM series Digital Flow meter.
Because the flow rate range is as wide as 0.1 to 200 L/h (measurement range ratio 2000:1), it can measure from very low flow rate in an idling state to large amount of flow rate in a high-load state when a fuel with a low heating value such as alcohol is used.
Also, since the flow detecting part is compact and its operating temperature range is -30 to +100°C, it can be installed inside an engine room to measure the actual driving fuel efficiency.
Features
System Configuration
Specification
|
FP-4135 On-Board Volumetric Flow Detector |
|
---|---|---|
Measurement item |
Flow / temperature |
|
Detection method |
Flow:Positive displacement (piston method) Temperature: Resistance temperature detector (Pt100 Ω) |
|
Measurable liquid | Gasoline, light oil, kerosene, class-A heavy oil, engine oil, petroleum-based general hydraulic oil, methanol, ethanol, mixture of alcohol and gasoline, and brake oil Please note that this equipment might not be used in the depositing condition.
|
|
Material for contacting liquid part (flow detecting part) |
Main unit/side board/ con rod/ crank shaft/ pin/ upper board: SUS303 |
|
Material for contacting liquid part (temperature detecting part) |
SUS316 | |
Measurement range |
Flow rate measurement range:0.1 to 200 L/h Temperature:-30 to 100 ℃ |
|
Measurement accuracy |
Flow rate:within ± 0.2 % of reading (measurement condition:20℃, 50%RH, Cleansol HS) Temperature:Class A |
|
Pressure loss |
4 kPa or less/at 60 L/h(gasoline) | |
Minimum resolution | 0.01 mL |
|
Filter (built-in a detector)* | Filtering capacity:33 µm(inlet side), 770 µm(outlet side) |
|
Applicable display unit | DF-2200 On-Board Flow Meter |
|
Output signal (flow rate) | Cable:FP-0015(5 m)/ FP-0016(10 m)/ FP-0017(20 m) Connector:TC1108-21B10-5M-1(detector side) TC1108-12B10-5F8.3(cable side) |
|
Output signal(temperature) | Cable:FP-0025(5 m)/FP-0026(10 m)/FP-0027(20 m) |
|
Inlet/Outlet port | Rc1/4 | |
General specification | Operating maximum pressure | 8 MPa |
Operating temperature range | Flow rate detecting part:-30 to 100 ℃(environment temperature, liquid temperature, with no condensation) Signal processing part:-30 to 70 ℃(environment temperature) |
|
Operating humidity range |
5 to 80 %RH(with no condensation) | |
Storage temperature range | Flow rate detecting part:-40 to 110 ℃(environment temperature, liquid temperature, with no condensation) Signal processing part:-40 to 80 ℃(environment temperature) |
|
Vibration
resistance (conducted) |
Acceleration rms value:27.3 m/s2 10 to 1000 Hz random vibration 1 hour for each direction of each 3 axis |
|
Shock resistance (not-conducted) |
Acceleration peak value:500 m/s2 |
|
Input power supply voltage | 12 VDC •Power is supplied from the Ono Sokki DF-2200 On-Board Flow Meter or the FM Series Digital Flow Meter |
|
Mass | Flow detecting part:approx.2.0 kg |
|
Accessory | Instruction manual |
|
Conforming standard | CE marking | EMC Directive:2014/30/EU standard EN61326-1 RoHs Directive:2011/65/EU standard EN50581 |
*When using it on a bench top engine bench, it is possible to extend the filter cleaning maintenance period by installing an external filter on the primary side of the flow meter. (Please contact us for the filter.)
Revised:2017/8/07