FP-213 FP-213S
Measurement
parameters
Flow rate Yes Yes
Temperature - -
Pressure - -
Detection method Volumetric flow rate detection (Piston method)
Applicable fluids Gasoline Yes Yes
Light oil Yes Yes
Kerosene Yes Yes
Standard petroleum
oil
Yes - (*1)
Alcohol fuels Option Option
Measurement range Flow rate 0.06 to 60 L/h (1 to 1000 mL/min, 0.02 to 16.7 mL/s)
Temperature - -
Pressure - -
Accuracy Flow rate Within ±0.0009 L/h
(from 0.06 to 0.18 L/h )
Within ±0.5 % of reading
(from 0.18 to 60 L/h)
Within ±0.5 % of reading
(over the entire 0.06 to 60 L/h range)
Temperature - -
Pressure - -
Pressure loss 8 kPa or less
(at 40 L/h, for gasoline)(*2)
0.01 kPa or less
(excluding filter pressure loss)
Maximum resolution 0.01 mL
Maximum flow rate pressure 980 kPa (*3) 980 kPa
Operating temperature range 0 to +65 °C (*3) 0 to +60 °C
Filter EH - 106 provided as standard
Weight Approx. 2 kg (including filter) Approx. 2.5 kg (including filter)

(*1): Please consult us for details.
(*2): If the inlet pressure is lower than the pressure low and if the outlet is open to the atmosphere, the instantaneous flow rate may be varied.
(*3): Please consult us if you require specifications other than given above.

    FP-2140H FP-2240HA FP-2140S
Measurement
parameters
Flow rate Yes Yes Yes
Temperature - Yes option
Pressure - Yes option
Detection method Volumetric flow rate detection (Piston method)
Applicable fluids Gasoline Yes Yes Yes
Light oil Yes Yes Yes
Kerosene Yes Yes Yes
Standard petroleum
oil
Yes Yes (*4)
Alcohol fuels Option Option Option
Measurement range Flow rate 0.3 to 120 L/h (*1) (5 to 2000 mL/min, 0.08 to 33.3 mL/s) 0.05 to 200 L/h(0.83 to 3333 mL/min, 0.01 to 55.5 mL/s)
Temperature - 0 to +99.9 °C -
Pressure - 0 to 980 kPa -
Accuracy Flow rate Within ±0.2 % of reading (over the entire 0.3 to 120 L/h range) Within ±0.2 % of reading (over the entire 0.05 to 200 L/h range)
Temperature - Pt 100Ω class B -
Pressure - ±0.5 % F.S. -
Pressure loss Within 2 kPa (at 60 L/h, for gasoline) (*2) 0.01 kPa or less (excluding pressure loss at filter section)
Maximum resolution 0.1 mL 0.01 mL
Maximum flow rate pressure 980 kPa (*3)
Operating temperature range 0 to +65 °C (*3) 0 to +60 °C
Filter EH - 1050 provided as standard
Weight Approx. 5 kg (including filter) Approx. 6 kg (including filter) Approx. 9 kg (including filter)

(*1): 0.3 to300 L/h flow rate measurement range can be provided. Please consult us for details.
(*2): If the inlet pressure is lower than the pressure low and if the outlet is open to the atmosphere, the instantaneous flow rate may be varied.
(*3): Please consult us if you require specifications other than given above.
(*4): In the case of high viscosity fluid, pressure loss compensation may become insufficient in the high flow areas.


    FP-215 FP-2250A
Measurement
parameters
Flow rate Yes Yes
Temperature - Yes
Pressure - Yes
Detection method Volumetric flow rate detection (Piston method)
Applicable fluids Gasoline Yes Yes
Light oil Yes Yes
Kerosene Yes Yes
Standard petroleum
oil
Yes Yes
Alcohol fuels Option Option
Measurement range Flow rate 1 to 1440 L/h (20 to 24000 mL/min, 0.3 to 400 mL/s)
Temperature - 0 to +99.9 °C
Pressure - 0 to 980 kPa
Accuracy Flow rate Within ±0.018 L/h (from 1 to 3.6 L/h)
Within ±0.5 % of reading (from 3.6 to 1440 L/h)
Temperature - Pt 100Ω class B
Pressure - ±0.5 % F.S.
Pressure loss 7.5 kPa or less (at 500 L/h <light oil>)(*1)
Maximum resolution 1 mL
Maximum flow rate pressure 3.4 MPa (*2) 980 kPa (*2)
Operating temperature range 0 to +65 °C (*2)
Filter Provided as standard
Weight Approx. 14 kg (including filter) Approx. 14 kg (including filter)

(*1): If the inlet pressure is lower than the pressure low and if the outlet is open to the atmosphere, the instantaneous flow rate may be varied.
(*2): Please consult us if you require specifications other than given above.

Signal Cable

Purpose of usage Model name Length Model name of detectors Model name of displays
For flow rate FP-0011 5 m FP-213/213S/2140H/2240HA
/215/2250A/2240H/2250
/3130/3132/3140/3142/3150
/3152/3130S/3132S(*2)
DF-2200
DF-0400A
(measurement module installed in the FM-2500A/1500)
DF-210B/210A/311/2410/2420
FM-0311 (measurement module installed in the FM-3100)
FP-0012 10 m
FP-0014 20 m
FP-0015 5 m FP-2140S (*1),FP-4135 DF-2200
DF-0400A
(measurement module installed in the FM-2500A/1500)
FM-0311 (measurement module installed in the FM-3100)
FP-0016 10 m
FP-0017 20 m
For temperature FP-0025 5 m FP-2140S (*1)
/2240HA/2250A/2240H/2250
FP-4135
DF-2200
DF-0400A
(measurement module installed in the FM-2500A/1500)
DF-211B/211A/2410/2420
FM-0311 (measurement module installed in the FM-3100)
FP-0026 10 m
FP-0027 20 m
For pressure FP-0035 5 m FP-2140S(*1)
2240HA/2250A/2240H/2250
FP-4135
DF-2200
DF-0400A
(measurement module installed in the FM-2500A/1500)
DF-211B/211A/241/2420
FM-0311 (measurement module installed in the FM-3100)
FP-0036 10 m
FP-0037 20 m

*1: Please consult us if you require specifications other than given above.
*2: If the inlet pressure is lower than the pressure low and if the outlet is open to the atmosphere, the instantaneous flow rate may be varied.
Model names in red-letter in above table are discontinued models

Revised:2012/09/03