Non-contact Thickness/Displacement Meter FAQ

How often is the Non-contact Thickness/Displacement Meter updated?

CL-5600/5610 The Non-contact Thickness Meter

 

The timing for updating a measurement value is shown as follows. When it moves at high speed, it measures the object intermittently.

 

Display value 0.5 s
Analog output terminal
(A-OUT<CL-5610>, THICK<CL-5600>)
20 ms
Analog output terminal
(SENSOR-A, SENSOR-B)
Frequency response range: 4,000 Hz Output it directly after adjusting a signal sensor.
RS-232C Minimum 50 ms (Changeable with the ability or program for the PC.)
BCD output 20 ms

 

 

VT-5210/5220/5710/5720 The Non-contact Displacement Meter

 

Processing only with an analog signal so defined in a frequency response range.

 

Frequency response range 4,000 Hz (VT-5210/5710)
10,000 Hz (VT-5220/5720)

 

Revised:2011/04/18