For high precision measurement of different fluid flows ranging from micro- to large-capacity flows.
These positive displacement flow meters are capable of making high precision measurement of different fluid flows ranging from micro- to large-capacity flows when used in combination with an FP-Series flow detector and a DF-Series flow meter.
You can choose the most appropriate item from our full line-up of the flow meters and counters to suit the applicable flow range, required measurement item and existing measuring site environments.
Features
Capable of making direct measurement of flow rates by mass.
Wide measurable range thanks to a flow rate ratio of 1:400 or more.
Capable of compensating for errors caused by pulsating or back flows by means of a function for detecting the direction of rotation.
High reproducibility and high-speed responsively result in superb reliability.
Simultaneous measurement of temperature and pressure is possible during flow rate measurement. (FP-2240HA/2250A)
Specifications Summary
Model |
FP-213S | FP-213 | FP-2140H | FP-2240HA | FP-215 | FP-2250A | |
---|---|---|---|---|---|---|---|
Measurement Parameters | Flow | Yes | Yes | Yes | Yes | Yes | Yes |
Temperature | Yes | Yes | |||||
Pressure | Yes | Yes | |||||
Applicable Liquid | Gasoline | Yes | Yes | Yes | Yes | Yes | Yes |
Light Oil | Yes | Yes | Yes | Yes | Yes | Yes | |
Kerosene | Yes | Yes | Yes | Yes | Yes | Yes | |
General Petroleum Oils | Yes | Yes | Yes | Yes | Yes | ||
Gasoline-Alcohol Mixture | Available by modification | Available by modification | Available by modification | Available by modification | Available by modification | ||
Measurement Range | Flow | 0.06 to 60 l/h |
0.3 to 120 l/h (*1) (5 to 2000 l/min, 0.1 to 30 ml/s) |
1 to 1440 l/h (20 to 24000 ml/min, 0.3 to 400 ml/s) |
|||
Temperature | 0 to +99.9°C | 0 to +99.9°C | |||||
Pressure | 0 to 980kPa | 0 to 980kPa | |||||
Accuracy | Flow | ±0.5% of reading value | ±0.0009 l/h (from 0.06 to 0.18 l/h) | ±0.2% of reading value | ±0.018 l/h (from 1 to 3.6 l/h) | ||
±0.5% of reading value (from 0.18 to 60 l/h) | ±0.5% of reading value (from 3.6 to 1440 l/h) | ||||||
Temperature | Class B | Class B | |||||
Pressure | ±0.5% of F.S | ±0.5% of F.S | |||||
Pressure Loss | 0.01kPa max. (except filter pressure loss) |
8kPa max. (at 40 l/h for gasoline) |
2kPa max. (at 60 l/h for gasoline) | 7.5kPa max. (at 500 l/h for light oil) |
|||
Max. Resolution | 0.01ml max. | 0.1ml max. | 1ml max. | ||||
Max. Flow Pressure | 980kPa | 980kPa (*2) | 3.4MPa (*2) | 980kPa (*2) | |||
Operating Temp. Range | 0 to +60°C | 0 to +65°C (*2) | |||||
Filter | EH-106 equipped as standard | EH-1050 equipped as standard | EH-101 equipped as standard | ||||
Weight (including Filter) | approx. 2.5kg | approx. 2kg | approx. 5kg | approx. 6kg | approx. 14kg |
*1 Available to modify measurement range up to 200 l/h upon request. *2 Consult us if modification expected.