Common specifications for

RP-1710/1730 series

Rotary Encoder


Connection method

Connector type

AC type

(100  to 240 VAC)
Model name: RP-1711, RP-1713, RP-1731, RP-1733
Cable side connector: supplied as standard

Please wire the cable (signal cable for AC power supply/signal output: sold separately)

Type AC power supply input type
Signal NJC-2010-RM (applicable connector: NJC-2010-PF)
Power supply NJC-203-RM (applicable connector: NJC-203-PF)
Connector for power supply

Pin No. Contents
1 AC
2 AC
3 F.G.
Connector for signal output

Pin No. Contents
Totem pole, collector, open collector Line driver
1 A A
2 B B
3 (Z) (Z)
4 COM -A
5 COM -B
6 COM COM
7 COM (-Z)
8 N.C N.C
9 N.C N.C
10 COM COM

*Item with parentheses are equipped with the RP-1713, RP-1733

DC type

(12 to 24 VDC)

Model name RP-1712, RP-1714, RP-1732, RP-1734

A connector for DC power supply and signal output are commonly used.

Cable side connector : supplied as standard

Please wire the cable. (Cable for DC power supply /signal output: sold separately)

Type AC power supply input type
Signal NJC-2010-RM (applicable connector: NJC-2010-PF)
Power supply

connector for power supply and signal output (shared)

Pin No. Contents
Totem pole, collector, open collector Line driver
1 A A
2 B B
3 (Z) (Z)
4 COM -A
5 COM -B
6 N.C N.C
7 COM (-Z)
8 DC+ DC+
9 DC- DC-
10 N.C N.C

*Item with parentheses are equipped with the RP-1714, RP-1734.

Terminal board type

AC type

(100 to 240 VAC)
Model nameRP-1711, RP-1713, RP-1731, RP-1733
Terminal board

terminal No. Contents
Totem pole, collector, open collector Line driver
1 A A
2 COM -A
3 B B
4 COM -B
5 COM COM
6 (Z) (Z)
7 COM (-Z)
8 N.C N.C
9 AC AC
10 AC AC

*Item with parentheses are equipped with the RP-1713, RP-1733.

DC type

(12 to 24 VDC)
Model nameRP-1712, RP-1714, RP-1732, RP-1734

Terminal board for power supply and signal output (shared)

Terminal No. Contents
Totem pole, collector, open collector Line driver
1 A A
2 COM -A
3 B B
4 COM -B
5 COM COM
6 (Z) (Z)
7 COM (-Z)
8 N.C N.C
9 DC+ DC+
10 DC- DC-

*Item with parentheses are equipped with the RP-1714, RP-1734.

Signal cable

No. Color Contents
AC type DC type
1 Blue Sig A (A)*1 Sig A (A)*1
2 Green Sig Com (-A)*1 Sig Com (-A)*1
3 White Sig B (B)*1 Sig B (B)*1
4 Gray Sig Com (-B)*1 Sig Com (-B)*1
5 Orange Sig Z (Z)*1, *2 Sig Z (Z)*1, *2
6 Yellow Sig Com (-Z)*1, *2 Sig Com (-Z)*1, *2
7 Red Sig Com Power supply +
8 Brown Sig Com Power supply -

For safety

Connector type

COM and F.G. are shared in the RP-1700 series. Please make sure to ground the power connector or it may cause malfunction or failure

 

Terminal board type

Use the M4 isolated crimp type terminal for connecting to the protective earth. COM and F.G. are shared in the RP-1700 series. Please make sure to ground the power connector or it may cause malfunction or failure.

Adjacent error

Adjacent error: actual pitch variation between any two adjacent pulse.

 

Protection class (IP)

Based on the JIS C 0920 (IEC 529), the protection classes are specified as follow. The RP-1700 series is compliant to IP65 by the performing test with the specified condition .

 

Example

IP 6 5 •••••• Dust-proof and jet-proof type

Second digit ••• Protection against water ingress
First digit ••• Protection against foreign bodies

 

First digit : Protection against human contact

 

First digit Protection against human contact Protection against foreign bodies
0 No special protection ——————
1 Protection against hands etc. Large forreign bodies, ƒÓ50mm or more
2 Protection against fingers etc. Medium-sized foreign bodies, ƒÓ12.5mm or more
3 Protection against wire , small tools etc Small-sized foreign bodies, ƒÓ2.5mm or more
4 Protection against wires etc. Granular foreign bodies, ƒÓ1mm or more
5 Limited protection against dust ingress
(No harmful deposit)
Dust deposits are permitted, but their volume must not affected the function of the unit
6 Tottally protected against dust ingress Dust-proof
X not prescribed ——————

Second digit : Protection against water ingress

Second digit Structure Test condition
0 No special protection ——————
1 Protection against vertically faling drops of water or condesation. Test duration: 10 minutes
Water equivalent to 1mm rainfall per minute from heights of 200 mm
2 Protection against falling drops of water, if the case is disposed up to 15° from vertical. Test duration: 10 minutes
Water equivalent to 3mm rainfall per minute.
Water dripping vertically onto a device titled to an angle of 15° from heights of 200 mm
3 Protection from sprashed water ( any direction up to 60 ° from the vertical) Test duration: 5 minutes
Water volume: 10 litres per minute Water splashing at any direction at angle up to 60° from the heights of 300 mm.
4 Protection from splashed water from all directions Test duration: 5 minutes
Water volume: 10 litres per minute
Water splashing from any direction at angle up to 180° from the heights of 300 mm..
5 Protection from water jets from a nozzle in all directions Test duration: at least 3 minutes Water volume: 12.5 litres per minute Water projected from a nozzle from any direction from the heights of 2.5 m.
6 Protection against heavy seas, or powerful water jets Test duration: at least 3 minutes
Water volume: 100 litres per minute
Powerful water jets or heavy seas from a nozzle from any diraction from the heights of 2.5 m
7 Protection against temporary immersion Test duration: 30 minutes
Immersion at depth of 1m
8 Protection against complete, continuous submersion in water Specified by the manufacture or customer
X not prescribed ——————

Revised:2011/08/01