When a water-wheel, which is a heart of
hydropower generation, is broken, it causes decrease in
power generation efficiency as well as breakage in other
parts. Early detection of abnormality and maintenance
are important. As abrasion or breakage appears in
abnormal vibration, monitoring vibration is an effective
way to detect abnormality. The VC-3200 vibration
comparator can monitor vibration periodically, detect
abnormal vibration and output alarm signal. This
application is helpful for predictive maintenance such
as prevention of an accident.
-
The VC-3200 can be set up three frequency
bands and make Pass/Fail judgment based on rms, peak or
power averaging calculated value (same for all bands) on each band. Also it has
effective functions such as the comparator delay time
setup function and auto operation function. The
comparator delay time setup function removes unwanted
signal at the time of starting measurement and the
automatic operation function can control a timing of
judgment by inputting a control signal from
external device such as PLC*. Although the VC-3200 can
be operated by 24VDC (22 to 26VDC) as standard, you have
an alternative to use it at 100 VAC by connecting the
optional AC/DC convertor VC-0352.
-
Connecting the VC-3200 to a PC via RS-232C
interface enables storing the measured data and so on.
-
By connecting a pair of commercially sold
headphones to the VC-3200, it is possible to make
hearing check of vibrating sound. Moreover, it can be
used instead of conventional stethoscopic probe. Output
signals are provided for each band, enabling an
observation for vibration phenomenon on each frequency
band.
* PLC: Programmable Logic
Controller
|