					As an inspection whether there is nick or 
						not on the gear box, sensory test by operator (touching 
						with hand, hearing the difference with stethoscopic 
						probe) is popular. This way of inspection cannot avoid 
						human-error and variation in quality. The judgment 
						by quantitative value is necessary in order to improve 
						the quality and stable supply of product. The VC-3200 
						can detect whether there is nick or not on the product 
						and make determination by quantitative value.
					The VC-3200 can setup three kinds of 
						frequency band and make Pass/Fail judgment of each band 
						based on the rms, peak or power averaging calculated 
						value (same for all bands). Also it 
						has comparator delay time setting functions and auto 
						operation function. The comparator delay time setting 
						function removes the unwanted signal at the time of 
						starting measurement, and the auto operation function 
						can control the timing of judgment by inputting a 
						control signal from external device such as PLC*. 
						Although the VC-3200 can be operated by 24VDC (22 to 
						26VDC) as standard, you have an alternative to use it at 
						100 VAC by connecting the optional AC/DC convertor 
						VC-0352.
				Connecting the VC-3200 to a PC via RS-232C 
					interface enables storing the measured data and so on.
					By connecting a pair of commercially sold 
						headphones to the VC-3200 it is possible to make hearing 
						check of the vibrating sound. Moreover, it can be used 
						instead of conventional stethoscopic probe. Output 
						signals are provided for each band, enabling an 
						observation for vibration phenomenon on each frequency 
						band separately. 
					
						* PLC: Programmable Logic 
						Controller |