As an inspection of abnormal sound from
compressor, hearing test by operator is popular. You
could choose another method using sound level meter etc.
because it is an inspection by sound, but it requires
enough space and much cost for anechoic box in order to
reduce the influence of the back ground noise. As an
alternative to these methods, the inspection which is
focused on the vibration is performed. Processing the
band-limited frequency allows the detection of abnormal
sound and automatic determination.
-
The VC-3200 can be setup three frequency
bands and make Pass/Fail judgment based on the rms,
peak on each band or power averaging calculated value
(same for all bands). Also it has
effective functions such as comparator delay time setup
function and auto operation function. The comparator
delay time setup function removes unwanted signal at the
time of starting measurement and the automatic operation
function can control the timing of judgment by
inputting a control signal from external device such as
PLC*. Although the VC-3200 can be operated by 24VDC (22
to 26VDC) as standard, you have an alternative to use it
at 100 VAC by connecting the optional AC/DC convertor
VC-0352.
-
Connecting the VC-3200 to a PC via RS-232C
interface enables storing the measured data and so on.
-
By connecting a pair of commercially sold
headphones to the VC-3200, it is possible to make hearing
check of the vibrating sound. Moreover, it can be used
instead of conventional stethoscopic probe. Output signals
are provided for each band, enabling an observation for
vibration phenomenon on each frequency band separately.
* PLC: Programmable Logic
Controller
|