					As an inspection of pump or the like 
						before delivery, visual checking by vibration meter, 
						hearing test by stethoscopic probe and sensory test 
						depending on human senses are popular. The VC-2200 helps 
						to perform steady and efficient automatic inspection 
						according to the numerical values. The VC-2200 also 
						enables to make Pass/Fail judgment by overall vibration 
						values of pump as well as inspection of the wrong 
						assembly of internal bearing.
					The VC-2200 can be setup two frequency 
						bands, and make Pass/Fail judgment based on the rms or 
						the peak value on each band. The VC-2200 has effective 
						functions such as comparator delay time setup function 
						for reduction of unwanted signal at the time of 
						measurement start, automatic operation function in order 
						to control the judgment timing by input the gate 
						signal from external equipments such as PLC*. You can 
						use the VC-2200 at 100VAC with VC-0352 AC/DC converter 
						as well as 24VDC (22 to 26VDC) as a power source.
				By connecting a pair of commercially sold 
					headphones to the VC-2200, it is possible to make an 
					auditory check of the vibrating sound. Moreover, it can be 
					used instead of conventional stethoscopic probe. Output 
					signals are provided for each band, enabling an observation 
					for vibration phenomenon on each frequency band separately.
				Also by installing VC-0423 integration 
					function (option), the signal from accelerometer is 
					integrated to enable measurement of velocity and 
					displacement. This can be combined with the comparator 
					function to make Pass/Fail judgment which is based on 
					velocity and displacement criteria. 
					* PLC: Programmable Logic 
					Controller |