This example shows how to measure the
flatness of camshaft from shaft center using linear
gauge sensors. The DG-2310 calculates the measured
values of maximum-minimum in order to obtain its
flatness by moving the shaft back and forth.
-
When transverse force is applied to linear
gauge sensor, we recommend an indirect measurement,
using jig etc. The indirect measurement prevents from
excessive load on sensor. However, please take notice
that sensor might cause less accuracy with an indirect
measurement.
|