There are 2 models such as the DG-4280 and DG-4240 which have a comparator function. The DG-4280 has the same comparator output function as the DG-410.
1. DG4280
Output condition (Decision criteria) | Decision output |
---|---|
Set polarity=Measurement polarity |
PRESET indicator is lit on red. PRESET output relay is turned ON. PRESET output is turned ON from the BCD out connector. |
2. DG4240
The contact output specification shows 3 decision results depending on the criteria such as LOWER/OK/UPPER.
Decision criteria | Decision | Display and output of the decision result |
---|---|---|
LOWER set value ≥ Display value | LOWER |
|
LOWER set value < Display value < UPPER set value | OK |
|
UPPER set value ≦ Display value | UPPER |
|
For further information, please refer to the FAQ of the DG-4280 and DG-4240.