This product is discontinued / Replaced by LA-7000 series Sound Level Meter (Click here)
  Ono Sokki Company, Ltd.


Replaced by LA-7000 series Integrating Sound Level Meter

HOME > Products Information > Discontinued > LA-5111/5120/2111
Integrating Sound Level Meter
  LA-5111  Precision Wide-range Sound Level Meter
 
LA-5120  Precision High-sensitivity Sound Level Meter
 
LA-2111  Multi-function Sound Level Meter
Outer Dimensions (PDF)

Photo (LA-5120 & LA-2111 Integrating Sound Level Meters)

The LA-2100/5100 series is the integrating type sound level meters, conforming to Type 1
regulated in the standard such like JIS, IEC and ANSI.

The meters can make sure high accurate measurement and expand possibilities of measurement in the field as well, because of featuring a wide dynamic range, multiple parameter display and long-term recording on-board memory.  Designed to be compact, durable and easy to operate, with the large and backlit LCD display, in addition, digital and quasi-analog bar graph indication of measured value.
Multiple parameter display can offer easy monitoring for an operator at the working site and measurement values of several parameters can be read out simultaneously, during a specified measurement interval, including Leq, LE, LMAX, LMIN, LPK and Lx.
For measurement data recording, three types of on-board memory support a variety of measurement applications. Mode of manual/Auto/Filter Scan can be used creatively, according to users' application.

A broad dynamic range of 100 dB (90dB measurement range plus 10dB peak margin) can be helpful to avoid changing or adjusting the measurement range on the meters for prevention of over/under error conditions due to fluctuations in the noise being measured.
All optional application software can be provided as the built-in software option and it can maintain operationality in good.

 

Features

  • Wide dynamic range of 100 dB

  • Seven items of LA, Leq, LAE, LX, LMAX, LMIN and Lpeak can be measured and indicated at the same time.

  • In the dual mode, sound pressure level can be measured with different time and frequency weighting applied at the same time.

  • Octave analysis (1/1 and 1/3 octave filters, 1/1 and 1/3 octave real-time analysis) options are also available.

 

Specifications

Model
LA-2111 LA-5111
LA-5120
Applicable standard

IEC 651/804 Type 2,
ANSI S 1.43 Type2

IEC 651/804 Type 1,
ANSI S 1.43 Type 1
Linearity range normal 75 dB
wide 100 dB
Frequency range 20Hz to 8kHz 20Hz to 20kHz 20Hz to 12.5kHz
Time weighting FAST, SLOW, IMPULSE 10ms, PEAK
Frequency weighting A, C, FLAT
Measuring range A  25 to 130dB 25 to 130dB 19 to 120dB
C 29 to 130dB 29 to 130dB 25 to 120dB
Flat 34 to 130dB 35 to 130dB 33 to 120dB
Measurement Items

Instantaneous SPL (LP), equivalent continuous SPL (Leq), sound exposure level (LAE), percentile SPL (Lx), maximum value (Max), minimum value (Min), peak hold (PEAKHOLD), TACTMAX (max. value in 1s interval)

Measurement time 1s, 3s, 5s, 10s, 20s, 30s, 1min, 3min, 4min 10s,
 5min, 10min, 15min, 30min, 1h, 8h, 24h, manual (max. 100h)
Sampling interval 20μs (Leq, LAE, PEAKHOLD, MAX, MIN)
Lx sampling 10ms, 0.1s, 0.5s, 1s, 5s
LP recording sampling 5ms, 10ms, 20ms, 50ms, 0.1s, 0.2s, 0.5s, 1s, 2s, 5s
Dual mode available to provided
(option)
provided
(standard)
provided
(standard)
Display Section Type LCD with backlight (128 x 64 dots)
Digital display Digital, 4-digit with 0.1 dB resolution, updated every 1s
Bar display normal range 60 dB range, 0.5 dB resolution, updated every 0.1s
wide range 90 dB range, 1 dB resolution, updated every 0.1s
Battery display Battery voltage (4 to 6V) is displayed in 8-segment bar graph
(indicator flashes for voltage of 3.8V or less)
Timer function Real-time clock (calendar function provided)
Battery backup Backup of memory data and real-time clock lasts for 5 months
(battery is charged during power on)
Memory Section Memory function
mode

OFF, MANU, AUTO, FILTER SCAN

panel condition

Power-off memory (initialization function provided)

Interface & Output Section RS-232C interface Baud rate : 2400, 4800, 9600, 19200 bps
AC output normal range 0.707Vrms (F.S.)
wide range 2.24Vrms (F.S.)
DC output normal range 2.5Vrms (F.S.), 0.5V/10dB
wide range 2.5Vrms (F.S.), 0.25V/10dB
General Power supply Four type AA batteries or AC adaptor
Battery life approx. 11hrs with alkaline batteries approx. 13hrs with alkaline batteries
Operating temperature range -10 to +50°C
Operating humidity range 30 to 90%RH
Outer dimensions 85(W) x 279(H) x 50(D)mm 85(W) x 347(H) x 50(D)mm
Weight approx. 500g approx. 550g

 

Contact Us Questions and Inquireies (Feedback form) Back to previous page