How to change the signal output of the RP-700 series to open collector output?

Please use the exclusive PA-330ZC Isolation Pulse Transmitter.

The PA-330ZC is the transmitter which removes the output circuit of 330 Ω resistances from the PA-330Z by a modification (option).

The following is the outline block diagram of the PA-330ZC. (Applicable model: RP-721, RP-732 and RP-704ZA)

 

 

 

Outer diameter diagram



PA-330ZC Specification

 

The number of input phases 3-phase
Input resistance 470 Ω
Input waveform Rectangular wave, duty ratio around 50 %
Input voltage L=0 to 4 V, H=8 to 12.5 V
Frequency 0 to 50 kHz
Output Collector output (Maximum rating DC 40V 50mA)
Delay time Around 2 µs between input to output
Power requirement AC 100 V Around 12 VA
Supplied voltage DC 12 V 0.15 A
Withstand voltage Between AC terminal and chassis: AC 1.5 KV
Between input common 1 and output common 2, between output common 2 and chassis: DC 500V
Between input terminal and chassis: DC 250 V
Isolation Between input common 1 and output common 2, between AC terminal and chassis: 100 MΩ or more (at 1000 V megohm)
Operating temperature range −5 to +40 ℃
Storage temperature range −10 to +70 ℃
Weight Around 4 kg
Terminal block JIS C 2805 Applicable to 1.25 to 3 crimp-type terminal

 

Revised:2002.02.15



© Copyright. ONO SOKKI CO., LTD. All Rights Reserved. | Terms of use | Privacy policy