No. |
Test MODE |
Test Description |
Measurement
Units, Other |
Speed Step |
Distance Step,
Other |
0 |
TEST
(Calibration and
equipment testing) |
Measurement of the distance, time, and average
speed from GATE ON to GATE OFF (white line detection possible) |
|
|
1 |
SS400-1000
(Standing-start
acceleration test) |
Measurement of the distance, time, and section
acceleration rate from the vehicle's standing-start position up
to the 400-m or 1000-m position |
Switched every
5 km/h
10 km/h
20 km/h |
Switched every
25 m (50 m after 100 m)
50 m (100 m after 200 m)
100 m (200 m after 400 m) |
2 |
ACCEL
(Passing acceleration test) |
Measurement of the distance, time, and section
acceleration rate from GATE ON (JUST speed function enabled) up
to the 400-m or 1000-m position |
3 |
COAST DOWN
(Coast-down test) |
Measurement of the coast-down time and the
coastdown coefficient from GATE ON (JUST speed function enabled)
up to the 400-m or 1000-m position |
Switched every
25, 50, 100 m |
4 |
BRAKE-1
(Brake test 1) |
Measurement of the initial speed at the braking
start time point and the braking distance, time, and average
deceleration until the stopping point |
(Calculates and displays MFDD) |
5 |
BRAKE-2
(Brake test 2) |
Measurement of the initial speed at
the braking start time point and the braking distance, time, and
section deceleration until the stopping point |
Measures deceleration using STEP
DATA |
Switched every
5, 10, 20 km/h |
Switched every
5, 10, 20 m |
6 |
METER CHECK
(Meter calibration) |
Comparison of the vehicle's speedometer with the
actual speed |
|
Desired number of times measured |
7 |
F-CONST
(Constant fuel consumption test) |
Measurement of the amount of fuel consumption and
the fuel consumption rate from GATE ON up to the 500-m or 1000-m
position |
|
Switched every
100, 500, 1000 m |
8 |
F-PATTERN
(Fuel consumption
pattern test) |
Measurement of the amount of fuel consumption and
the fuel consumption rate while changing the running pattern |
|
Auto GATE OFF
possible after
2 or 5 patterns |
9 |
D.STEP PRINT
(Fixed distance) |
Continuous printing of the distance, time, and
instantaneous speed from GATE ON (white line detection possible)
to GATE OFF |
|
Switched every
50, 250, 500 m |